Common Problems And Solutions When Installing Pneumatic Butterfly Valves

Oct 06, 2025

Leave a message

1. The butterfly plate is installed in the wrong direction

Phenomenon: Medium leakage, increased operating torque or the valve cannot be fully closed.

Solution: Disassemble the valve again, adjust the direction of the butterfly plate to be consistent with the flow direction, and reinstall it.

 

2. The actions of the actuator and the butterfly plate are not synchronized

Phenomenon: The cylinder moves but the butterfly plate does not respond, or the movement direction is opposite.

Solution: Check if the air source interface is connected in reverse, or adjust the internal mechanical structure of the actuator (such as the gear direction).

 

3. Leakage at the sealing surface

Phenomenon: There is still medium passing through after the valve is closed.

Solution: Check whether the butterfly plate is deformed and whether the sealing ring is damaged. Replace the parts or readjust the sealing gap if necessary.